Dometic Penguin II: model-specific electrical ratings

For a Penguin II, use the complete model suffix before reading the electrical table. Dometic’s2016 manual lists 651815.80X at 13.1 A compressor rated load plus 2.6 A fan rated load;651815.30X has different entries.

The locked-rotor column is separate. It is not a measured startup waveform, and the Penguin name alone does not identify a generator requirement.

The suffix changes the running-current sum

Selected rows in the September 2016 installation manual; amperes
ModelCompressor ratedFan ratedCompressor locked rotor
651815.80X13.12.663.0
651815.30X12.53.561.0

The manufacturer installation document identifies these rows separately. Adding the rated compressor and fan values gives 15.7 A for the.80X example and 16.0 A for the.30X. A larger compressor entry does not necessarily mean the larger combined running sum.

651815.80X rated-load componentsCompressor: 13.1 AFan: 2.6 A
The fan’s 2.6A belongs in the rated-load total; the 63A locked-rotor specification is a different measurement.

Generator guidance has a scope

That manual gives general 3.5 kW/5 kW guidance for one/two units and expressly says to consider total RV power use, altitude and maintenance. Other loads still matter. Do not turn the 63 A locked-rotor entry into a claimed running load or multiply it by voltage and call the result a mandatory generator size.

When gathering information for an installer, record the roof unit and the indoor control or air-distribution assembly. A replacement has to work with both. Use the wider air-conditioning selection guide for the supply and installation questions, and have qualified service assess roof, mains and refrigerant work.

A repair quote is evidence of one job

A 2015 Canyon Star owner in the Penguin failure discussion reported a 2018 quote of$1,200 for the unit and$300 labor. The$1,500 sum describes that old quote, not today’s installed price. It says nothing about a fleet failure rate.

Ask a current repairer to itemize diagnosis, the proposed unit, compatible controls and installation. Comparing two totals without those details can hide a different scope of work. Keep the old quote’s date attached whenever using it as a reference.